UPCOM Telekomunikasyon • Shielded data LAN cable

CAT 7A+ S/FTP Cable

CAT 7A+ S/FTP cable is built for high-bandwidth structured cabling projects that need 23 AWG bare copper conductors, pair-by-pair foil shielding and an overall tinned copper braid for stable signal integrity up to 1500 MHz. It is a strong fit for installations where EMI control, shielded construction and reliable copper transmission matter.

  • 23 AWG bare copper
  • Up to 1500 MHz
  • S/FTP shielding
  • PVC / HFFR / PE jacket options
CAT 7A+ S/FTP LAN cable reel
Shielded Category 7A+ cable for structured copper network installations.

CAT 7A+ S/FTP cable overview

This CAT 7A+ S/FTP cable is designed for shielded copper data infrastructure where higher bandwidth headroom and stronger protection against external interference are priorities. The structure combines individually foil-screened pairs with an overall tinned copper braid, helping the cable perform more consistently in electrically demanding installation paths.

For projects that balance technical performance with practical installation requirements, the cable also offers jacket alternatives in PVC, HFFR or PE. That makes it easier to align the same core cable family with indoor building routes, low-smoke requirements or project-specific outdoor preferences.

1500 MHz Suitable for high-frequency data LAN installations.
23 AWG Solid bare copper conductor structure.
S/FTP Individual pair foil plus overall braided shield.
305 / 500 m Typical packing options listed in the datasheet.

CAT 7A+ S/FTP cable construction

Conductor

Solid bare copper core

The cable uses 23 AWG bare copper conductors to support stable electrical performance in structured cabling environments.

Insulation

Skin / foam / skin PE insulation

This insulation structure supports transmission stability while helping preserve the cable geometry required for controlled impedance.

Shielding

Pair foil + overall braid

Each pair is wrapped with Al-Pet foil and the full cable is protected by tinned copper wire braiding for stronger shielding performance.

Why S/FTP shielding matters

  • Helps reduce the effect of electromagnetic interference in busier cable pathways.
  • Supports cleaner transmission where shield continuity and signal stability are important.
  • Improves suitability for higher-performance shielded copper infrastructures.

Jacket options for different project needs

  • PVC for standard indoor routing where permitted by project requirements.
  • HFFR for low-smoke, halogen-free expectations in selected building specifications.
  • PE for routes where the project prefers a PE outer sheath option.

Standards note: This cable family is presented with compliance references including EIA/TIA-568-C.2, ISO/IEC 11801, IEC 61156-5 and EN 50173-1 in the existing datasheet. For general structured cabling background, you can review the official ISO/IEC 11801 and IEC 61156-5 references.

CAT 7A+ S/FTP cable technical properties

The table below reorganizes the current datasheet values into a more readable format for buyers, spec writers and installers evaluating a shielded Category 7A+ copper cable.

Mechanical propertiesValueElectrical properties at 20°CValue
Copper weight34.5 kg/kmMax. conductor resistance9.5 Ω / km
Min. bending radius during draw-in62 mmMax. resistance unbalance< 2%
Min. bending radius permanently installed32 mmMin. insulation resistance5000 MΩ x m
Max. tensile strength92 NMutual capacitance43 pF / m
Min. crush resistance1000 N / 10 cmMax. capacitance unbalance1600 pF / km
Min. impact10 impactsImpedance at 100 MHz100 ± 5 Ω
Installation temperature0°C to +50°CVelocity of propagation79%
Operating temperature-30°C to +70°CDelay skew25 ns / 100 m
Packing305 / 500 mMin. TCL / coupling attenuation / transfer impedance / test & operating voltageLevel 2 / Type 1 / Class 1 / 1000 V / 125 V

Practical note: Jacket choice can change weight and fire-performance classification. If your project is driven by CPR or installation environment requirements, confirm the exact build before quotation and approval.

Applications for CAT 7A+ S/FTP cable

CAT 7A+ S/FTP cable is suited to high-performance copper LAN projects where shielding quality and bandwidth margin are more important than using a simpler unshielded construction. Based on the current product information, the cable is used across structured cabling scenarios including Ethernet, Fast Ethernet, Gigabit Ethernet, 10GBase-T and PoE / PoE+ environments.

Enterprise cabling

Office and commercial buildings

A practical choice for structured building networks where shielded copper routes are preferred for performance consistency and noise control.

Industrial preference

Electrically busier pathways

The S/FTP design is relevant where cable routes run close to equipment or infrastructure that can increase interference risk.

PoE readiness

Data and power on one channel

Suitable for projects that combine network transmission with PoE or PoE+ powered devices within a shielded copper design approach.

When to choose this cable

  • When the project wants a shielded cable family with higher bandwidth headroom.
  • When pair shielding and an overall braid are preferred instead of a lighter screen design.
  • When the route, environment or specification makes EMI management more important.

When to compare alternative LAN cables

How to choose CAT 7A+ S/FTP cable

This short selection flow helps turn the datasheet into a practical decision checklist for consultants, contractors and export buyers.

01

Define the installation environment

Start with the routing conditions: building interior, conduit path, equipment room density and whether the project prefers a shielded copper network throughout the channel.

02

Match the jacket to the project specification

Choose PVC, HFFR or PE according to the required fire behaviour, environmental exposure and specification language used by the project.

03

Confirm bandwidth and shielding expectations

If the design needs a high-bandwidth shielded cable with pair foil and overall braid, CAT 7A+ S/FTP can be the stronger fit than lighter shielded or unshielded alternatives.

04

Check installation limits early

Before ordering, review bending radius, tensile strength, installation temperature and packing format so the field team does not work against the cable design.

05

Link the cable with the wider project cluster

For broader family comparison, review the full fiber optic and data LAN cable range. If the project specification is driven by fire-performance language, also review the CPR compliant cables guide. For ducted installation workflows, you may also look at UP-S-LUB-20 cable blowing lubricant.

FAQ about CAT 7A+ S/FTP cable

What does S/FTP mean on a CAT 7A+ cable?

S/FTP means the cable combines individual foil shielding on each twisted pair with an overall screen. On this product family, the overall screen is described as a tinned copper braid, which supports stronger shielding performance than a basic unshielded build.

Where is CAT 7A+ S/FTP cable typically used?

It is used in structured copper cabling projects where buyers want a shielded LAN cable with higher bandwidth headroom, better EMI control and support for Ethernet, Gigabit Ethernet, 10GBase-T and PoE-oriented network layouts.

Does CAT 7A+ S/FTP cable support PoE applications?

The current product information lists PoE and PoE+ among the supported applications. Final suitability should still be checked against the full channel design, installation practice and the active equipment plan.

Which outer sheath should I choose: PVC, HFFR or PE?

Choose the sheath according to the installation environment and specification. PVC is typically used for standard indoor routes, HFFR is preferred where low-smoke halogen-free performance is requested, and PE may be chosen for project routes that require a PE jacket option.

How should I compare CAT 7A+ S/FTP with other LAN cable options?

Start with shielding level, bandwidth target, project specification and route conditions. If you need a simpler or lower-bandwidth option, compare this page with CAT 7 S/FTP, CAT 6 SF/UTP and CAT 5e U/UTP within the same UPCOM cable family.

Need the CAT 7A+ S/FTP datasheet or a family comparison?

Use the datasheet for exact technical confirmation, then compare this page with nearby shielded and unshielded cable families to match the project specification more precisely.