19-inch industrial rack · Gasketed body · Floor standing

IP55 Free Standing Enclosure

An IP55 free standing enclosure houses 19-inch equipment in dusty or damp industrial locations. The published family uses a fully welded steel framework, adjustable front and rear mounting profiles and gasketed panels and cable entry.

Size the enclosure for equipment, cabling, service access and heat load. Cooling openings, cable glands and door choices must form a configuration that preserves the required ingress protection.

15U–42UPublished rack family
1200 kgEvenly distributed load
19-inchAdjustable mounting
100 mmPublished base module
IP55 free standing industrial enclosure with rack mounting profiles
19-inch industrial rack · Gasketed body · Floor standing

IP55 Enclosure Construction

ItemDatasheet information
FrameworkFully welded steel; 1.5 mm galvanized steel bearing framework
Rear / side panels1.5 mm steel
Plinth1.5 mm galvanized steel; base module 100 mm high
Load rating1200 kg evenly distributed
Mounting profilesAdjustable 19-inch front/rear profiles with U markers
SealingGasketed panels and base cable entry
Front door opening135°
GroundingConnection terminals provided on panels
ColorRAL 7035 light gray listed; confirm selected finish

The rated load is an evenly distributed cabinet load. Confirm installation, floor capacity, fixation and equipment distribution for your project; do not interpret it as the load rating of every shelf or accessory.

Enclosure Sizes and Ordering

The description lists 15U–42U and width/depth combinations of 600 × 600, 600 × 800, 800 × 600, 800 × 800, 800 × 1000 and 800 × 1200 mm. The PDF also contains an extended order-code table with external height and plinth dimensions. Specify both usable U height and external dimensions.

Published order-code exampleWidthBody + plinth heightDepthDoors
UP IP55-6012060-CC600 mm1200 + 100 mm600 mmSingle
UP IP55-8018060-CC800 mm1800 + 100 mm600 mmSingle
UP IP55-80200100-CC800 mm2000 + 100 mm1000 mmSingle

CC denotes the color code in the PDF. Confirm the rack height, rail spacing, door type and configuration-specific dimensions on the final drawing.

Cooling, Cable Entry and IP55 Protection

The datasheet lists top-mounted fan modules and air inlet filters as options. An unqualified fan cutout, open cable hole or different door can change the enclosure's protection. Specify the complete cooling and gland arrangement and request confirmation of the resulting IP rating.

Provide equipment heat dissipation in watts, ambient conditions, dust/water exposure and the required internal temperature. A fan or filter choice cannot be sized from U height alone.

Specify an Industrial Rack Enclosure

  1. State usable U height, equipment dimensions and total distributed weight.
  2. Allow depth for rear connectors, bend radii and service access.
  3. Define door, lock, cable gland and panel requirements.
  4. Provide ambient conditions and equipment heat load for cooling selection.
  5. Confirm IP protection for the assembled configuration, floor fixation, finish and delivery requirements.