Data Center Solutions

UPCOM data center solutions cover cold aisle containment, colocation racks, integrated micro data centers, precision cooling and modular UPS. Select a rack-level system for an edge site or plan cooling and power for a room with multiple rack rows.

Space and accessCold aisle, co-location and micro data centers
Power and coolingModular UPS and precision cooling
OperationsRack KVM and environmental monitoring

Data center infrastructure by application

Cold aisle containment

Face two rack rows across the supply-air aisle. Sliding end doors and roof panels separate supply air from warm exhaust. Specify the number and width of the server rack cabinets, aisle width and end-door clearance.

Rack dimensions and aisle options (PDF, p. 2)

Colocation racks and cages

Two- and four-compartment cabinets divide rack space between tenants. Mesh partitions can enclose a separate rack area. Identify the tenant access points and any shared fibre patch panels before choosing the compartment layout.

Cabinet compartments and rack layouts (PDF, p. 3)

Integrated micro data centers

A single IT rack and an adjacent in-row cooling bay combine protected power, monitoring and access control for edge installations. Compare bay widths, drawings and project sizing inputs.

Dimensioned micro data center drawing (PDF, p. 5)

Precision cooling

Choose in-row or raised-floor air delivery. The 20–150 kW range includes direct expansion (DX) and chilled-water (CW) systems. For sizing, specify heat load and design temperatures.

Precision cooling options (PDF, p. 6)

Modular UPS

Size the modules and batteries for the protected load in kW and kVA. Specify runtime at that load, planned growth and redundancy during a module outage. List the feed and outlet requirements for each rack PDU.

UPS modules and backup power (PDF, p. 7)

Rack KVM consoles

A 1U drawer combines an LCD, keyboard, touchpad and 8- or 16-port KVM switch. Choose local access or specify an IP-capable configuration for remote access.

KVM console configurations (PDF, p. 8)

Environmental monitoring

Select temperature, humidity, smoke, water or vibration sensors for the locations to be monitored. Specify the number of monitoring points and the required alarm outputs.

Sensor types and applications (PDF, p. 8)


Data center solution gallery

Cold aisle enclosure showing the end-door assembly and roof panels
Cold aisle containment · end doors
Mesh partition enclosing a co-location rack area
Partitioned co-location area
Colocation cabinet with four independently accessible equipment compartments
Four-compartment colocation rack
Closed micro data center cabinet with IT and cooling bays
Integrated IT and cooling bays
Floor supply-air grilles between two server rack rows
Raised-floor cooling supply
Full-height view down a rack aisle with floor grilles supplying cooling air
Raised-floor cooling · installed aisle
Open modular UPS cabinet showing the fitted power modules and service access
Modular UPS · power modules
Pull-out rack KVM console open with screen, keyboard and pointing device
Rack-mounted KVM console

Request a project quote

Tell us which solution you are planning, the project location and your design requirements. If you already have a layout, identify the rack cabinet types and give the rack dimensions used in the drawing.

Data center project
Data Center Solutions
1×