Data Center Solutions

Micro Data Center

The UPCOM single-rack micro data center combines a 19-inch IT rack with in-row cooling, UPS, an intelligent rack PDU and environmental monitoring. Specify one rack for an edge site or add equipment bays for a larger installation.

Rack and cooling configuration

IT bay600 or 800 mm wide
Cooling bay300 mm wide, in-row
Cooling duty and UPSSized to the project load
Reference W × D × H900 × 1,350 × 2,080 mm

Open cabinet with the cooling column beside the IT equipment bay
Open cabinet
Red micro data center cabinet with closed IT and cooling bays
Red enclosure · doors closed
Open red micro data center showing the cooling fans beside the IT equipment space
Red enclosure · doors open
Micro data center front panel with a display, access reader and door handle
Front access panel and handle

What is included in an integrated micro data center?

IT and cooling bays

The equipment rack and cooling unit sit side by side. Measure the deepest server with rails, connectors and cables installed. The 19-inch rack dimensions guide explains how to check usable depth. Reserve space for rear access and any rack-mount fibre patch panels in the IT bay.

Power and backup

The UPS supplies the IT equipment through an intelligent rack power distribution unit. Specify the protected IT load, required battery runtime at that load, available input supply and outlet mix.

Monitoring and access control

The system combines environmental monitoring and controlled access. List the events your team needs to receive and the monitoring platform it uses so the interface can be agreed in the offer.

Fire detection and suppression

Fire detection and suppression are part of the system design. Include site requirements and identify who will coordinate the local acceptance of the proposed configuration.


Micro data center dimensions and layouts

The illustrated single-rack assembly measures 900 × 1,350 × 2,080 mm (W × D × H). It pairs a 600 mm IT bay with a 300 mm cooling bay. An 800 mm IT bay or additional cabinets require a separate layout. Allow space beyond the cabinet footprint for door swing and service access.

Side, front and plan dimensions of the 900 mm wide reference assembly
Reference dimensions
Multi-cabinet layout with additional equipment bays
Multi-bay arrangement
Isometric line drawing showing the cooling column, open door and adjacent IT bay
Cabinet interior · isometric drawing

What does UPCOM need to quote an edge site?

Send the rack height and usable U, equipment depth, initial and future IT load in kW, required UPS runtime in minutes, available supply, site conditions, delivery country and number of locations. If the system will expand, specify what must be installed at handover and what may be added later.

Use the micro data center RFQ and bid comparison workbook (Excel) to record site inputs and compare supplier offers against the same load and runtime.

Prepare your micro data center RFQ or compare supplier quotations using worked examples.

For a room that already provides conditioned air and protected power, see the standalone server rack cabinets. The rack cabinet selection guide also covers network and wall-mount enclosures.


Request a micro data center quote

Select a layout and include your IT load, usable rack space and required UPS runtime in the message.